Reverse Laminar Air Flow Unit
Reverse Laminar Air Flow Unit

Reverse Laminar Air Flow Unit

MOQ : 1 , , Millimeter

Reverse Laminar Air Flow Unit Specification

  • Voltage
  • 230V AC, 50 Hz
  • Power Consumption
  • 500 Watt
  • Filters
  • Pre-filter (10 micron), HEPA Filter (0.3 micron)
  • Application
  • Powder Containment, Capsule Filling, Sampling, Weighing Applications
  • Filter Type
  • HEPA & Pre-Filter
  • Type
  • Reverse Laminar Air Flow Unit
  • Floor
  • SS 304 Chequered Plate
  • Air Flow
  • Vertical, Reverse Direction Air Flow
  • Door
  • Front Acrylic Door
  • Material
  • Stainless steel
  • Air Volume
  • Approx. 900-1500 m/hr
  • Dimension (L*W*H)
  • 1200 mm x 900 mm x 2100 mm
  • Feature
  • Low Noise, User Friendly Operation, Ergonomic Design
  • Weight
  • Approximately 180 kg
  • Nozzle
  • Air Nozzle for Sampling Arm
  • Condition
  • New
  • Frame Material
  • SS 304
  • Lighting
  • LED Lighting inside working area
  • Thickness
  • 1.2 mm (Body Panel)
 

Reverse Laminar Air Flow Unit Trade Information

  • Minimum Order Quantity
  • 1 , , Millimeter
  • Supply Ability
  • 7 Millimeters Per Week
  • Delivery Time
  • 3-4 Week
  • Sample Available
  • Yes
  • Main Domestic Market
  • Maharashtra, All India
 

About Reverse Laminar Air Flow Unit



Experience the Best in contamination control with our Elite Reverse Laminar Air Flow Unit, now available at a Special Rate! Designed for sterling efficiency, this pre-fabricated, floor-mounted unit boasts a microprocessor-based control panel with feather touch operation and a digital display for real-time air velocity and filter life monitoring. Quiet operation (<65 dB), high illumination (>800 Lux), and ergonomic design make it ideal for capsule filling, weighing, and sampling. Benefit from robust stainless steel construction, superior HEPA filtration, and audio-visual safety alarms. Take advantage of this Special Promotion from Indias leading exporter, manufacturer, and supplier.

Elite Reverse Laminar Air Flow Unit: Versatile Applications

The Reverse Laminar Air Flow Unit is widely used in demanding environments such as pharmaceutical powder containment, capsule filling, precise weighing, and sampling applications. Its advanced, ergonomic design ensures user comfort while maintaining a sterile workspace. The units vertical reverse airflow, high-efficiency HEPA and pre-filters, and smooth stainless steel surfaces make it suitable for laboratories, research centers, production facilities, and cleanrooms alike, offering optimal protection for sensitive processes and personnel.


Swift Delivery, Global Export, and Certified Quality

We cater to export markets across the globe with competitive list prices and prompt delivery schedules. Standard units are typically available for delivery within 24 weeks, and samples can be arranged upon request. Our products are supplied with all standard certifications to meet regulatory and industry requirements, helping secure your peace of mind. Contact us for precise asking prices, detailed certificates, and flexible export terms tailored for international clients seeking the Best in air flow technology.


FAQs of Reverse Laminar Air Flow Unit:


Q: How does the Reverse Laminar Air Flow Unit benefit powder containment and pharmaceutical applications?

A: The unit provides a sterile, low-contamination environment by using high-efficiency HEPA and pre-filters in a reverse air flow system, which is vital for safe powder containment, capsule filling, weighing, and sampling, effectively protecting both product integrity and operator safety.

Q: What control features enhance the user experience with this unit?

A: A microprocessor-based control panel with feather touch controls, digital display for air velocity and filter life, LED lighting, and an audio-visual safety alarm ensure intuitive, user-focused operation and enhanced workplace safety.

Q: Where can this Reverse Laminar Air Flow Unit be installed?

A: It is suitable for installation in any laboratory, pharmaceutical production area, research facility, or cleanroom requiring containment and precise air quality control. The floor-mounted, pre-fabricated design and casters provide mobility and straightforward setup.

Q: What makes the filtration process in this unit highly effective?

A: Equipped with a 95% efficient pre-filter and a HEPA filter capturing 99.97% of particles down to 0.3 microns, the unit ensures superior filtration, extending filter life monitoring for consistent, reliable performance in sensitive operations.

Q: When can customers expect delivery of the Reverse Laminar Air Flow Unit and are samples available?

A: Standard delivery time is 24 weeks after order confirmation. Samples are available for review upon request, with all units shipped fully certified and prepared for global export.